Page 1 --- Showing records 1 - 50 (out of 74)
| Item # |
Description |
Price |
Cart |
POWER SUPPLY REPLACEMENT
POWER SUPPLY REPLACEMENT
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~6
Normal Stocking Item.
ARC-11011
Manufacturer:
ARCVISION TECHONLOGY CORP
PWR SPLY TANSFORMER 12V 1.5A
• 12VDC Power Supply 1.5Aa
• Output Connector 2.5mm x 5.5mm
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
ARM-12VDC1.5A
Manufacturer: n/a
POWER SUPPLY 12VDC 1.5AMP
PWR SUPPLY 12VDC 1.5AMP
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
24VDC 1 AMP. "F" PORT
You must be logged in to request more information about products.
Login or Call
for Pricing.
Clearance Item
(call to verify pricing
and availability)
DUAL POWER INSERTER
Dual Power Inserter (5-2300MHz)
Provides power for both polarities of LNB or two inline Amplifiers and
also provides power for MMDS Down Convertor and Amplifiers.
Specifications
•Bandwidth 5.-2300MHz
•Insertion Loss 1dB
•Return Loss 15dB Min
•Isolation 40dB Min
•DC Voltage 18VDC Max
•Max Current 500mA
•Transformer UL LISTED
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~1
Special Order Item.
POWER SUP. 12VDC./150 MA W/F-P
POWER SUPPLY WITH F-FEMALE
(120VAC, 12VDC, 150mA)
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~1
Normal Stocking Item.
PWR SUP 24VDC 600MA w DC PLUG
You must be logged in to request more information about products.
Login or Call
for Pricing.
Clearance Item
(call to verify pricing
and availability)
24V DC 600MA FOR ASK-PDS-38E
You must be logged in to request more information about products.
Login or Call
for Pricing.
Clearance Item
(call to verify pricing
and availability)
PWR SUP 120VAC - 24VDC 600MA F
POWER SUPPLY WITH F-FEMALE
OUTPUT 120VAC, 24VDC, 600m
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
PWR SUP CHARGER .75AMPS @12VDC
12VDC power limited output.
75A continuous supply current @ 12.5 to 13.9VDC.
Filtered and electronically regulated outputs.
16.5VAC/20VA input from UL Listed, Class 2 transformer.
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup.
Maximum charge current .5 amp.
Automatic switch to stand-by battery when AC fails.
AC input and DC output LED indicators.
Low battery and AC Fail supervision form “C" contacts (1 amp @ 28VDC).
Lifetime Warranty.
Specification Sheet: AX-AL100UL.pdf
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~1
Normal Stocking Item.
12VDC 10AMP UL LISTED POWER SU
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
10 AMP POWER SUPPLY CHARGER 24
10 AMP Power Supply Charger, 24VDC output, 115VAC 60Hz 4.4 amp input, w/ multi output access power controller
Specification Sheet: AX-AL1024ULAMCB.pdf
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
REPLACEMENT POWER BOARD FOR AL
24VDC output.
8 amp of continuous supply current, 10 amp during alarm.
115VAC 60Hz, 4.4 amp input.
Filtered and electronically regulated outputs.
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup.
Maximum charge current 3.6 amp.
Zero voltage drop upon transfer to battery backup.
AC input and DC output LED indicators.
AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
Low battery and battery presence supervision
(form "C" contact rated @ 1 amp 28VDC).
Specification Sheet: AX-AL1024ULXB.pdf
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
12/24 VDS ACCESS FACP SUP
Model AL175UL power supply/charger converts 115VAC 60Hz
input, into two (2) PTC protected 12VDC or 24VDC
@ 1.75 amp Class 2 Rated power limited
supply current outputs.
Agency Listings
UL Listed for Access Control Systems (UL294)
CUL Listed - CSA Standard C22.2 No.205-M1983
Signal Equipment. File# BP5864.
CSFM - California State Fire Marshal Approved.
File# 7315-1335:106. MEA - NYC Department
of Buildings Approved. NFPA 101 (Life Safety).
Features/Specifications
12VDC or 24VDC selectable output.
1.75 amp of continuous supply current.
Two (2) PTC protected Class 2 Rated power limited outputs.
115VAC 60Hz, .6 amp.
Filtered and electronically regulated outputs.
Dry Trigger Input. Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup.
Maximum charge current .4 amp.
Automatic switch to stand-by battery when AC fails.
AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
Dry trigger output supervision (form "C" contact rated @ 1 amp 28VDC).
AC input and DC output LED indicators Lifetime Warranty
Enclosure
Dimensions:
8.5"H x 7.5"W x 3.5"D.
1/2" and 3/4" combination knockouts.
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~3
Normal Stocking Item.
5 OUTPUT UL POWER SUPPLY 12/24
Model AL300ULM is specifically designed for use with access control systems and accessories.
This unit converts a 115VAC 60Hz input into five (5) PTC protected Class 2 Rated power limited outputs
rated @ 2 amp each, with an output current of 12VDC or 24VDC @ 2.5 amp total.
Model AL300ULMR is a Red Cabinet version of this product.
Agency Listings
UL Listed for Access Control Systems (UL294)
Power Supplies for use with Burglar Alarm Systems (UL603) Hospital Signaling and Nurse Call Equipment (UL1069)
Power Supplies for Fire Protective Signaling Systems (UL1481) CUL Listed - CSA Standard C22.2 No.205-M1983, Signal Equipment
File# S4707.CSFM -California State Fire Marshal Approved
File# 7315-1335:100. MEA - NYC Department of Buildings Approved. File# 168-92-E Vol. VI.
Features/Specifications
Power Supply/Charger 12VDC or 24VDC selectable output 2.5 amp supply current.
115VAC 60Hz, 1.45 amp input. Filtered and electronically regulated outputs
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup Maximum charge current .7 amp
Zero voltage drop upon transfer to battery backup. AC input and DC output LED indicators.
AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC).
Lifetime Warranty
Multi-Output Module:
Five (5) PTC protected outputs.Class 2 Rated power limited outputs.
Current limit is 2 amp @ 12VDC or 24VDC per output. Provides power for Fail Safe and/or Fail Secure locking devices
Fire Alarm Panel or Access Control System trigger inputs NO or NC supervised trigger input and
polarity reversal trigger input (.4 amp draw from FACP) Lifetime Warranty.
Enclosure
Accommodates up to two (2) 12VDC/7AH batteries
Dimensions:
13.5"H x 13"W x 3.25"D
1/2" and 3/4" combination knockouts
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
1 OUTPUT UL POWER SUPPLY 12/24
Model AL300ULXR power supply/charger converts a
115VAC 60Hz input, to a 2.5 amp of continuous supply
current @ 12VDC or 24VDC non-power limited output. Red Enclosure
Agency Listings
UL Listed for Access Control Systems (UL294)
Power Supplies for use with Burglar Alarm Systems (UL603),
Hospital Signaling and Nurse Call Equipment (UL1069),
Power Supplies for Fire Protective Signaling Systems (UL1481),
CUL Listed - CSA Standard C22.2 No.205-M1983, Signal Equipment.
File# S4707.CSFM - California State Fire Marshal Approved
File# 7315-1335:100.MEA - NYC Department of Buildings Approved
File# 168-92-E Vol. VI. NFPA 72 Compliant
Features/Specifications
12VDC or 24VDC selectable output
2.5 amp of continuous supply current output
Class 2 Rated power limited output.
115VAC 60Hz, 1.45 amp inputFiltered and
electronically regulated outputs
Short circuit and thermal overload protection
Built-in charger for sealed lead acid or gel type battery backup
Maximum charge current .7 amp. Zero voltage drop upon transfer to battery backup
AC input and DC output LED indicators AC fail supervision
(form "C" contact rated @ 1 amp 28VDC)
Low battery and battery presence supervision
(form "C" contact rated @ 1 amp 28VDC) Lifetime Warranty
Enclosure
Accommodates up to two (2) 12VDC/7AH batteries.
Dimensions:
13.5"H x 13"W x 3.25"D
1/2" and 3/4" combination knockouts
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
12/24VDC 4A SUPPLY
Model AL400UL power supply converts a 115VAC
60Hz input, to 12VDC @ 4 amp or 24VDC @ 3 amp
of continuous supply current Class 2 Rated power
limited output.
Agency Listings
UL Listed for Access Control Systems (UL294)
Burglar Alarms Systems (UL603)
Hospital Signaling and Nurse Call Equipment (UL1069)
Power Supplies for Fire Protective Signaling Systems
(UL1481) ULC Listed File # S4707.
CSFM - California State Fire Marshal Approved.
File # 7315-1335:100.
MEA - NYC Department of Buildings Approved.
File # 168-92-E NFPA 72 Compliant.
Features/Specifications
12VDC or 24VDC selectable output.
4 amp @ 12VDC or 3 amp @ 24VDC of continuous
supply current output. Class 2 Rated power limited output.
115VAC 60Hz, 1.45 amp input.Filtered and
electronically regulated outputs.
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type
battery backup.Maximum charge current .7 amp.
Zero voltage dropupon transfer to battery backup.
AC input and DC output LED indicators.
AC fail supervision (form "C" contact rated @ 1 amp
28VDC). Low battery supervision (form "C" contact rated
@ 1 amp 28VDC).Lifetime Warranty.
Enclosure
Dimensions: 12.25"H x 7.75"W x 4.5"D.
1/2 and 3/4 combination knockouts.
Similar Altronix Products AL400ULX 4 amp
@ 12VDC or 3 amp @ 24VDC. Larger Enclosure.
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
UL/ADA 4AMP SUPPLY
Model AL400ULADA is specifically designed to interface between the FACP and indicating devices
to supply the additional power needed for a Fire Alarm System to conform to ADA regulations. For
both retrofit and new installations, the model AL400ULADA Fire Alarm Indicating Circuit Power Supply
will save time and expense, while efficiently providing the power needed to drive additional horns,
strobes and bells required under the ADA.
This unit allows compatibility between 12VDC fire alarm control panels and 24VDC ADA strobes
and other signaling devices. The AL400ULADA comes complete with power supply, enclosure,
transformer and ample room for standby batteries. On-board supervisory relays are incorporated
for remote status reporting and trouble indications at the fire panel.
Agency Listings
UL Listed Control Units and Accessories for Fire Alarm Systems (UL864).
File# S5075. CSFM - California State Fire Marshal Approved
File# 7315-1335:101. MEA - NYC Department of Buildings Approved.
Features/Specifications
12VDC or 24VDC selectable output 4 amp max total alarm current
115VAC 60Hz., 1.45 amp. Interfaces with one (1) FACP Class B indicating circuit
Compatible with 12VDC or 24VDC fire panels Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup
Maximum charge current .7 amp. Zero voltage drop upon transfer to battery backup.
AC input and DC output LED indicators. AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC).
Lifetime Warranty
Enclosure
Accommodates up to two (2) 12VDC/12AH batteries
Dimensions:
15.5"H x 12"W x 4.5"D
1/2" and 3/4" combination knockouts
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~2
Normal Stocking Item.
UL 12/24VDC 4A SUPPLY
Features/Specifications 12VDC or 24VDC selectable output
4 amp @ 12VDC or 3 amp @ 24VDC of continuous supply
current output.Class 2 Rated power limited output.
115VAC 60Hz, 1.45 amp input.Filtered and
electronically regulated outputs. Short circuit and
thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup
Maximum charge current .7 amp Zero voltage drop
upon transfer to battery backup AC input and DC
output LED indicators AC fail supervision
(form "C" contact rated @ 1 amp 28VDC)
Low battery and battery presence supervision
(form "C" contact rated @ 1 amp 28VDC) Lifetime Warranty
Enclosure:
Accommodates up to two (2) 12VDC/7AH batteries
Dimensions:
13.5"H x 13"W x 3.25"D
1/2" and 3/4" combination knockouts
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~2
Normal Stocking Item.
OFF-LINE SWITCHING POWER SUPPL
Model AL400ULXB power supply/charger converts a 115VAC 60Hz input,
to 12VDC @ 4 amp or 24VDC @ 3 amp of continuous supply current output.
Class 2 Rated power limited output.
Agency Listings
UL Recognized Component for Access Control Systems (UL294),
Power Supplies for use with Burglar Alarm Systems (UL603),
Hospital Signaling and Nurse Call Equipment (UL1069),
Power Supplies for Fire Protective Signaling Systems (UL1481)
File# S4707.NFPA 72 Compliant
Features/Specifications
12VDC or 24VDC selectable output
4 amp @ 12VDC or 3 amp @ 24VDC of continuous supply current output.
Class 2 Rated Power limited output.115VAC 60Hz, 1.45 amp input.
Filtered and electronically regulated outputs
Short circuit and thermal overload protection
Built-in charger for sealed lead acid or gel type battery backup
Maximum charge current .7 amp.Zero voltage drop upon transfer to battery backup
AC input and DC output LED indicators.
AC fail supervision (form "C" contact rated @ 1 amp 28VDC)
Low battery and battery presence supervision
(form "C" contact rated @ 1 amp 28VDC)
Lifetime Warranty
Board
Dimensions (approximate):
4.6"W x 7.5"L x 2.7"H
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
ACCESS POWER CONTROLLER w/POWE
Model AL600ULACM converts a 115VAC 60Hz input into eight (8) independently controlled
12VDC or 24VDC non power limited fuse protected Fail-Safe and/or Fail-Secure outputs with
a total of 6 amp continuous supply current.
The fire alarm disconnect feature enables emergency egress in the event the fire alarm system is
activated. It is individually selectable for any or all of the eight (8) outputs. Model AL600ULACMCB
is a PTC protected version of this unit.
Agency Listings
UL Listed for Access Control Systems (UL294) CUL Listed - CSA Standard C22.2 No.205-M1983,
Signal Equipment. File# BP6714. CSFM - California State Fire Marshal Approved
File# 7315-1335:106. MEA - NYC Department of Buildings Approved. File# 18-98-E Vol 3.
Features/Specifications
Power Supply/Charger: 12VDC or 24VDC selectable output 6 amp of continuous supply current
115VAC 60Hz, 1.9 amp input Filtered and electronically regulated outputs.
Short circuit and thermal overload protection. Maximum charge current .7 amp.
Zero voltage drop upon transfer to battery backup. AC input and DC output LED indicators.
AC fail supervision (form "C" contact rated @ 1 amp 28VDC). Low battery and battery presence supervision
(form "C" contact rated @ 1 amp 28VDC). Lifetime Warranty
Access Power Controller:
Eight (8) Access Control System outputs
Eight (8) fuse protected Fail-Safe and/or Fail-Secure 12VDC or 24VDC power outputs.
Eight (8) fuse protected 12VDC or 24VDC auxiliary power outputs (unswitched).
Red LEDs indicate outputs are triggered (relays energized).
Eight (8) Access Control System trigger inputs
Eight (8) normally open (NO) inputs.
Eight (8) open collector inputs Any combination of the above
Fire Alarm Disconnect:Fire Alarm Disconnect (latching or non-latching) is individually
selectable for any or all of the eight (8) outputs.Normally open (NO) or normally closed (NC) dry contact input.
Polarity reversal input FACP signaling circuit. Fire Alarm trigger LED indicates that the Fire Alarm Disconnect has been activated.
Fire Alarm output relay for triggering auxiliary reporting devices (form "C" contact rated @ 1 amp 28VDC).
Lifetime Warranty
Enclosure
Accommodates up to two (2) 12VDC/12AH batteries
Dimensions:
15.5"H x 12"W x 4.5"D
1/2" and 3/4" combination knockouts
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
UL 12/24VDC 6A SUPPLY
Model AL600ULX power supply/charger converts a 115VAC 60Hz input, to a
6 amp of continuous
supply current @ 12VDC or 24VDC non-power limited output
Agency Listings
UL Listed for Access Control Systems (UL294) Power Supplies for Fire Protective
Signaling Systems (UL1481) CUL Listed - CSA Standard C22.2 No.205-M1983
Signal Equipment File# S4707.CSFM -California State Fire Marshal Approved
File# 7315-1335:104.MEA - NYC Department of Buildings Approved
File# 168-92-E Vol. III.FM Approved NFPA 72 Compliant
Features/Specifications
12VDC or 24VDC selectable output 6 amp of continuous supply current
115VAC 60Hz, 1.9 amp input Filtered and electronically regulated outputs.
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup.
Maximum charge current .7 amp.Zero voltage drop upon transfer to battery
backup.
AC input and DC output LED indicators AC fail supervision
(form "C" contact rated @ 1 amp 28VDC).
Low battery and battery presence supervision
(form "C" contact rated @ 1 amp 28VDC).
Lifetime Warranty
Enclosure
Accommodates up to two (2) 12VDC/7AH batteries.
Dimensions:
13.5"H x 13"W x 3.25"D.
1/2" and 3/4" combination knockouts.
Specification Sheet: AX-AL600ULX.pdf
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~2
Normal Stocking Item.
SAME AS AX-AL600UL/ADA BUTTEMP
Model AL602ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery charger.
It maybe connected to any 24 volt Fire Alarm Control Panel (FACP).
Primary applications include Notification Appliance Circuit (NAC such as strobes and
horns) expansion support to meet ADA requirements. It also provides auxiliary power to support system accessories.
The unit delivers regulated and filtered 24 volt power to Class B or Class A NAC loop circuits. Additionally, a separate 1.0A auxiliary output with reset forfour (4)-wire smoke detectors is available. The 6.5 amp rated supply current can be divided between the four (4) outputs for powering
NAC devices.
Each output is rated at 2.5 amp max. and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output).
An individual output of 4 amp is achieved by paralleling 2 outputs. In non alarm condition independent loop supervision for Class A and/or Class B FACP NAC circuits is provided. In the event of a loop trouble the FACP will be
In addition, there are common trouble output terminals (NC, C, NO) which are used to indicate general loop/system trouble. A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP.
Two (2)FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the four (4) outputs.
The unit also features “Loop Output" trouble memory indication to help identify troublesome sporatic problems. Model is available in a largerenclosure
AL602ULADAJ.
Agency Listings
UL Listed Control Units and Accessories for Fire Alarm
Systems (UL864).File# S5075. CSFM California State Fire Marshal Approved File# 7315-1335:103. MEA –NYC Department of Buildings Approved FM Approved.
Features/Specifications
Power Supply/Charger 24VDC output.
6.5 amp max total alarm current
115VAC 60Hz. 1.45 amp.
Short circuit and thermal overload protection. Built-in charger for sealed lead acid or gel type battery backup.
Maximum charge current .7 amp. Zero voltage drop upon transfer to battery backup. AC input and DC output LED indicators. AC fail supervision (form "C" contact rated@ 1 amp 28VDC).
Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC).
Lifetime Warranty.
Logic Board:
Class 2 Rated power limited outputs. Two (2) Class A or two (2) Class B FACP inputs. Two (2) Class A or four (4) Class B Indicating Circuits.
Two (2) Class B outputs may be paralleled for more power on an indicating circuit. One (1) Aux. Power Output @ 1 amp supply current (w/Battery Back Up)
Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and unnecessary service calls.
LEDs indicate a prior fault (short, open, ground) has occured on one or more signaling circuit outputs. 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification
appliances (strobes) continue to operate.
Horn/Strobe sync protocols include: Wheelock Gentex , System Sensor , Faraday, Amseco Temporal Code 3 Mode Steady Mode. Input to Output
Follower Mode (maintains synchronization of notification appliance circuits).March Time Compatible with 24VDC or 12VDC
fire panels Common Trouble inputs and outputs. Ground fault detection Lifetime Warranty
Enclosure
Accommodates up to two (2) 12VDC/12AH batteries.
Dimensions: 15.5"H x 12"W x 4.5"D.
1/2" and 3/4" combination knockouts.
You must be logged in to request more information about products.
Login or Call
for Pricing.
Normal Stocking Item.
NAC POWER EXTENDERS 6.5 AMP 12
NAC POWER EXTENDERS
6.5 AMP
12 OR 24VDC
TWO CLASS A OR FOUR CLASS B OUTPUTS
SYNC PROTOCOLS
• The AL602UL2ADA, AL802UL2ADA and AL1002UL2ADA are extremely cost
effective voltage regulated remote NAC Power Extenders. They may be
connected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary
applications include Notification Appliance Circuit (NAC) expansion
(supports ADA requirements) and will provide auxiliary power to support
system accessories.
AL602UL2ADA
• 24VDC or 12VDC
rated @ 6.5 amp max.
• Two (2) Class A or
four (4) Class B outputs.
AL802UL2ADA
• 24VDC or 12VDC
rated @ 8 amp max.
• Two (2) Class A or
four (4) Class B outputs.
AL1002UL2ADA
• 24VDC rated
@ 10 amp max.
• Two (2) Class A or
four (4) Class B outputs
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
PWR SUP BRD 6 12 24 V
The AL624 Linear Power Supply / Charger will convert a
low voltage AC input to a low voltage DC output. This
general purpose power supply has a wide range of
applications for access control, security and CCTV system
accessories that require additional power.
Specifications:
Selectable 6-12-24VDC power limited output.
1.2 amp continuous supply current at 6-12VDC.
750mA continuous supply current at 24VDC.
Filtered and electronically regulated output.
Built-in charger for sealed lead acid or gel type batteries.
Maximum charge current 300mA.
Automatic switchover to stand-by battery when AC Fails.
AC input and DC output LED indicators.
Thermal and short circuit protection with auto reset.
Fused battery protection (circuit breakers available).
Snap Trac compatible (order Altronix model #ST3).
DIN Rail mount version available
(order Altronix model #DPS1).
Includes battery leads.
Extremely compact design.
Board dimensions: 3"L x 2.5"W x 1.5"H
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~10
Normal Stocking Item.
12/24 VDC 6.5 AMP W/4 CLASS A
Model AL642ULADA is an extremely cost effective 6.5 amp voltage regulated remote NAC Power Extender. It may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and will provide auxiliary power to support system accessories.
The unit delivers regulated and filtered 24 volt power via up to eight (8) Class B, four (4) Class A or combination of Class B and Class A Notification Appliance Circuits. Additionally, the unit can supply up to 1 amp from continous AUX output and up to 1 amp from AC disconnected AUX ouput. The 6.5 amp rated supply current can be divided between the four (4) outputs for powering notification appliances and the AUX outputs.
Each output is rated at 2.5 amp max (total not to exceed 6.5 amp), and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). An individual output of 4 amp is achieved by paralleling 2 outputs.
In non-alarm condition units provide independent loop supervision for Class A and/or Class B FACP NAC circuits. In the event of a loop trouble the FACP will be notified via steered inputs (input 1 or input 2). In addition, there are common trouble output terminals (NC, C, NO) which are used to indicate general loop/system trouble.
A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be connected to power extender inputs. These inputs can then be directed to control supervision and power delivery to any combination of the four (4) outputs. The unit also feature “Loop Output" trouble memory indication to help identify troublesome sporatic loop problems.
Agency Listings
UL Listed Control Units and Accessories for Fire Alarm Systems (UL864).File# S5075.
CSFM - California State Fire Marshal Approved
File# 7315-1335:109.MEA - NYC Department of Buildings Approved FM Approved.
Features/Specifications
Power Supply/Charger 24VDC output 6.5 amp max total alarm current.
115VAC 60Hz., 3.2 amp.Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup
Maximum charge current .7 amp Zero voltage drop upon transfer to battery backup.
AC input and DC output LED indicators AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC) Lifetime Warranty
Logic Board:
Class 2 Rated power limited outputs.
Two (2) Class A or two (2) Class B FACP inputs
Two (2) NC dry contact trigger inputs
Four (4) Class A or four (4) Class B Indicating Circuits
Two (2) Class B outputs may be paralleled for more power on an indicating circuit.
One (1) Aux. Power Output @ 1 amp supply current (w/Battery Back Up).
One (1) Aux. Power Output @ 1 amp supply current (w/o Battery Back Up).
Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and
unnecessary service calls. LEDs indicate a prior fault (short, open, ground) has occured on one or
more signaling circuit outputs.
2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification
appliances (strobes) continue to operate Horn/Strobe sync protocols include: Wheelock , Gentex , System Sensor ,
Faraday, Amseco Temporal Code 3 Mode Steady Mode.
Input to Output Follower Mode (maintains synchronization of notification appliance circuits).
March Time Compatible with 24VDC or 12VDC fire panels Common Trouble inputs and outputs.
Ground fault detection Lifetime Warranty
Enclosure
Accommodates up to two (2) 12VDC/12AH batteries.
Dimensions:
18"H x 14.5"W x 4.625"D
1/2" and 3/4" combination knockouts
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
AL-802ULADA BOARD ONLY
REPLACEMENT BOARD
You must be logged in to request more information about products.
Login or Call
for Pricing.
Normal Stocking Item.
UL/ADA 8 AMP SUPPLY
Model AL802ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery charger. It may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC such as strobes and horns) expansion support to meet ADA requirements. It also provides auxiliary power to support system accessories.
The unit delivers regulated and filtered 24 volt power to Class B or Class A NAC loop circuits. Additionally, a separate 1.0A auxiliary output with reset for four (4)-wire smoke detectors is available. The 8 amp rated supply current can be divided between the four (4) outputs for powering NAC devices. Each output is rated at 2.5 amp max., and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization.
All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). An individual output of 4 amp is achieved by paralleling 2 outputs. In non-alarm condition independent loop supervision for Class A and/or Class B FACP NAC circuits is provided. In the event of a loop trouble the FACP will be notified via the steered input (input 1 or input 2).
In addition, there are common trouble output terminals (NC, C, NO) which are used to indicate general loop/system trouble. A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the four (4) outputs.
The unit also features “Loop Output" trouble memory indication to help identify troublesome sporatic problems.
Model is available in a larger enclosure AL802ULADAJ.
Agency Listings
UL Listed Control Units and Accessories for Fire Alarm Systems (UL864).File# S5075.
CSFM - California State Fire Marshal Approved File# 7315-1335:107.
MEA - NYC Department of Buildings Approved.FM Approved.
Features/Specifications
Power Supply/Charger: 24VDC output 8 amp max total alarm current 115VAC 60Hz., 1.45 amp.
Short circuit and thermal overload protection Built-in charger for sealed lead acid or gel type battery backup.
Maximum charge current .7 amp Zero voltage drop upon transfer to battery backup.
AC input and DC output LED indicators AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC).
Lifetime Warranty
Logic Board:
Class 2 Rated power limited outputs.
Two (2) Class A or two (2) Class B FACP inputs
Two (2) NC dry contact trigger inputs
Two (2) Class A or four (4) Class B Indicating Circuit.
Two (2) Class B outputs may be paralleled for more power on an indicating circuit.
One (1) Aux. Power Output @ 1 amp supply current (w/Battery Back Up).
Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and
unnecessary service calls. LEDs indicate a prior fault (short, open, ground) has occured on one or
more signaling circuit outputs.
2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification
appliances (strobes) continue to operate.
Horn/Strobe sync protocols include: Wheelock , Gentex , System Sensor , Faraday, Amseco.
Temporal Code 3 Mode.Steady Mode Input to Output Follower Mode (maintains synchronization of notification appliance circuits).
March Time Compatible with 24VDC or 12VDC fire panels. Common Trouble inputs and outputs
Ground fault detection Lifetime Warranty
Enclosure
Accommodates up to two (2) 12VDC/12AH batteries
Dimensions:
15.5"H x 12"W x 4.5"D.
1/2" and 3/4" combination knockouts
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
12/24VDC 2.5A LINEAR
Model LPS3 will convert a low voltage AC input to a low voltage
12VDC/24VDC @ 2.5 amp of continuous
supply current output.
Features/Specifications
12VDC or 24VDC selectable output
2.5 amp continuous supply current
Transformer requirements:
16VAC/56VA for 12VDC output (Altronix Model # T1656).
28VAC/100VA for 24VDC output (Altronix Model # T2428100).
Filtered and electronically regulated output
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup
Maximum charge current .5 amp
Automatic switch over to stand-by battery.
Fused battery protection (circuit breaker available)
AC input and DC output LED indicators.
Lifetime Warranty
Board
Dimensions (approximate):
3.5"W x 6.5"L x 1.75"H
http://www.altronix.com/index.php?pid=2&model_num=LPS3
Specification Sheet: AX-LPS-3.pdf
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~1
Special Order Item.
ACCESS POWER CONTROLLER
This unit distributes and switches power to access
control systems and accessories. It converts a
115VAC 60Hz input into sixteen (16) independently
controlled 12VDC or 24VDC fuse protected outputs.
These power outputs can be converted to dry form
“C" contacts. Outputs are activated by an open collector
sink or normally open (NO) dry trigger input from
an Access Control System, Card Reader, Keypad,
Push Button, PIR, etc. The unit will route power to a
variety of access control hardware devices including:
Mag Locks, Electric Strikes, Magnetic Door Holders, etc.
Outputs will operate in both Fail-Safe and/or Fail-Secure
modes. The FACP Interface enables Emergency Egress,
Alarm Monitoring, or may be used to trigger other auxiliary
devices. The fire alarm disconnect feature is individually selectable
for any or all of the sixteen (16) outputs.
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
4 POS POWER DIST. BD
The PD4 is a power distribution module, designed to convert a single AC or
DC intput into four (4) individually fuse protected outputs.
Features/Specifications
Operates up to 28VAC/28VDC
Four (4) fuse protected outputs, fuses are rated @ 3.5 amp (up to 5 amp fuses
may be used)
Surge Supression Power Output LED indicator
Lifetime Warranty
Board:
Dimensions (approximate):
3.25"W x 5.25"L x 1"H
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~2
Normal Stocking Item.
4 POS POWER DIST.W/CB
The PD4CB is a power distribution module, designed to convert a single AC or
DC intput into four (4) individually PTC protected outputs.
Features/Specifications
Operates up to 28VAC/28VDC
Four (4) PTC protected outputs PTCs are rated @ 2.5 amp.
Surge Supression Power Output LED indicator
Lifetime Warranty
Board:
Dimensions (approximate):
3.25"W x 5.25"L x 1"H
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~1
Normal Stocking Item.
8 POS POWER DIST.BD
The PD8 is a power distribution module, designed to convert a single AC or
DC input into eight (8) individually fuse protected outputs.
Features/Specifications
Operates up to 28VAC/28VDC
Eight (8) fuse protected outputs, fuses are rated @ 3.5 amp (up to 5 amp fuses
may be used)
Surge Supression Power Output LED indicator
Lifetime Warranty
Board:
Dimensions (approximate):
3.25"W x 5.25"L x 1"H
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~1
Normal Stocking Item.
8 POS POWER DIST.W/CB
The PD8CB is a power distribution module, designed to convert a single AC or
DC intput into eight (8) individually PTC protected outputs.
Features/Specifications
Operates up to 28VAC/28VD
Eight (8) PTC protected outputs PTCs are rated @ 2.5 amp.
Surge Supression Power Output LED indicator
Lifetime Warranty
Board:
Dimensions (approximate):
3.25"W x 5.25"L x 1"H
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~2
Normal Stocking Item.
POWER DISTRIBUTION 8 POSITION
12VDC or 24VDC up to 10 amp, or
24VAC or 28VAC up to 12 amp
(AC not evaluated by UL)
Eight (8) PTC protected outputs.
PTCs are rated @ 2.5 amp.
Surge suppression.
Power Output LED indicator.
Specification Sheet: AX-PD8ULCB.pdf
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
PWR SUP SUPERVISORY
12VDC output,1 amp of continuous supply current.
Transformer requirements:
16VAC/20VA for 12VDC output (Altronix Model # TP1620). Filtered and electronically regulated outputs. Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup. Maximum charge current .2 amp.
AC input and DC output LED indicators. AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
Low battery and battery presence supervision. (form "C" contact rated @ 1 amp 28VDC).Lifetime Warranty.
Dimensions (approximate): 2.75"W x 5.25"L x 1.5"H
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
12/24 10AMP SUPPLY
Model SMP10 power supply/charger converts low
voltage AC input, to a 12VDC or 24VDC @ 10 amp of
continuous supply current output.
Features/Specifications
12VDC or 24VDC selectable output.
10 amp continuous supply current.
Transformer requirements:
28VAC/175VA for 12VDC @ 10 amp output
(Altronix Model # T2428175). 28VAC/175VA
for 24VDC @ 6 amp output
(Altronix Model # T2428175). 28VAC/300VA for
24VDC @ 10 amp output (Altronix Model # T2428300).
Filtered and electronically regulated outputs.
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup.
Maximum charge current .7 amp.
Zero voltage drop upon transfer to battery backup.
AC input and DC output LED indicators.
Lifetime Warranty.
Board:
Dimensions (approximate):
4.25"W x 2.3"L x 7"H
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~1
Normal Stocking Item.
12VDC/10A COMPLETE
Model SMP10PMC12X power supply/charger converts a
115VAC 50/60Hz input, to a 12VDC @ 10 amp of
continuous supply current output. Model SMP10C12X is a
non-supervised version of this unit.
Features/Specifications
12VDC output 10 amp of continuous supply current output
115VAC 50/60Hz, 1.45 amp input.
Filtered and electronically regulated outputs
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup
Maximum charge current .7 amp Zero voltage drop upon transfer to battery backup.
AC input and DC output LED indicators.
AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
Low battery supervision (form "C" contact rated @ 1 amp 28VDC).
Lifetime Warranty
Enclosure
Accommodates up to two (2) 12VDC/7AH batteries
Dimensions:
13.5"H x 13"W x 3.25"D.
1/2" and 3/4" combination knockouts
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
12 VDC 16 AMP SUPERVISED POWER
Model SMP16PMC12X power supply/charger converts a
115VAC 50/60Hz input, to a 12VDC @ 16 amp of continuous
supply current output.
Features/Specifications
12VDC output 16 amp of continuous supply current output.
115VAC 50/60Hz, 1.45 amp input.
Filtered and electronically regulated output
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup
Maximum charge current .7 amp Zero voltage drop upon transfer
to battery backup AC input and DC output LED indicators.
AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
Low battery and battery presence supervision
(form "C" contact rated @ 1 amp 28VDC).
Power On-Off switch Lifetime Warranty
Enclosure
Accommodates up to two (2) 12VDC/12AH batteries
Dimensions:
15.5"H x 12"W x 4.5"D
1/2" and 3/4" combination knockouts
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
PWR.SUP.BRD 6 TO 24V
Features/Specifications 6,12VDC or 24VDC selectable
Output 2.5 amp continuous supply current.
Transformer requirements:
16VAC/40VA for 6VDC output (Altronix Model # TP1640)
16VAC/40VA (Altronix Model # TP1640)
or 24VAC/100VA (Altronix Model # T2428100)
or 28VAC/100VA (Altronix Model # T2428100)
for 12VDC output. 28VAC/100VA for 24VDC output
(Altronix Model # T2428100) Filtered and electronically
regulated outputs. Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup.
Maximum charge current .5 amp AC input and DC output
LED indicators Lifetime Warranty
Board:
Dimensions (approximate):
3"W x 3.5"L x 2"H
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~8
Normal Stocking Item.
PWR.SUP.SUPERVISED
Model SMP3PM power supply/charger converts low voltage AC input
to a 12VDC or 24VDC @ 2.5 amp of continuous supply current output.
Features/Specifications
12VDC or 24VDC selectable output
2.5 amp continuous supply current
Transformer requirements:
16.5VAC/40VA to 28VAC/40VA minimum for 12VDC output
(Altronix Model #s TP1640 or T2428100)
28VAC/85VA for 24VDC output (Altronix Model # T2428100).
Filtered and electronically regulated outputs
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup
Maximum charge current .3 amp
Zero voltage drop upon transfer to battery backup.
AC input and DC output LED indicators.
AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
Low battery supervision (form "C" contact rated @ 1 amp 28VDC).
Lifetime Warranty
Board:
Dimensions (approximate):
4"W x 7"L x 1.75"
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~1
Normal Stocking Item.
PWR.SUP.BRD 6 TO 24V
Features/Specifications 6VDC,12VDC
or 24VDC selectable output.
4 amp of continuous supply current. Transformer requirements:
16.5VAC/40VA for 6VDC output (Altronix Model # TP1640).
24VAC/100VA or 28VAC/100VA for 12VDC output
(Altronix Model #T2428100). 28VAC/175VA for 24VDC output
(Altronix Model # T2428175). Filtered and electronically
regulated outputs. Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup.
Maximum charge current .5 amp AC input and DC output LED
indicators. Lifetime Warranty
Board Dimensions (approximate):
3"W x 3.5"L x 2"H
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~11
Normal Stocking Item.
4A SUPERVISED PWR SUPPY
Features/Specifications 12VDC or 24VDC selectable
output. 4 amp of continuous supply current.
Transformer requirements:
24VAC/100VA or 28VAC/100VA for 12VDC output
(Altronix Model #T2428100). 28VAC/175VA for
24VDC output (Altronix Model # T2428175).
Filtered and electronically regulated outputs. Short circuit
and thermal overload protection. Built-in charger for
sealed lead acid or gel type battery backup.
Maximum charge current .3 amp. Zero voltage
drop upon transfer to battery backup.
AC input and DC output LED indicators.
AC fail supervision (form "C" contact rated @ 1 amp
28VDC). Low battery supervision (form "C" contact
rated @ 1 amp 28VDC). Lifetime Warranty
Board:
Dimensions (approximate):
4.125"W x 7"L x 1.125"H
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~1
Normal Stocking Item.
5PM W/CABINET/LOCK
Features/Specifications 12VDC or 24VDC selectable output
4 amp of continuous supply current output 115VAC 50/60Hz
.65 amp input. Filtered and electronically regulated outputs
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup
Maximum charge current .5 amp Zero voltage drop upon transfer to
battery backup.AC input and DC output LED indicators.
AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
Low battery supervision (form "C" contact rated
@ 1 amp 28VDC) Lifetime Warranty
Enclosure:
Accommodates up to zero (0) 12VDC/7AH battery
Dimensions:
13.5"H x 13"W x 3.25"D
1/2" and 3/4" combination knockouts.
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
12/24 PS BOARD AND CHARGER
Model SMP7 power supply converts low voltage AC input
to a 12VDC or 24VDC @ 6 amp
of continuous supply current output.
Features/Specifications
12VDC or 24VDC selectable output.
6 amp of continuous supply current.
Transformer requirements:
28VAC/175VA for 12VDC output
(Altronix Model # T2428175).
28VAC/175VA for 24VDC output
(Altronix Model # T2428175).
Filtered and electronically
regulated outputs.
Short circuit and thermal overload protection.
Built-in charger for sealed lead
acid or gel type battery backup.
Maximum charge current .6 amp.
Zero voltage drop upon transfer to
battery backup.
AC input and DC output LED indicators.
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~1
Normal Stocking Item.
12/24 6A B/O W/OUTPUT
Model SMP7PM power supply converts low voltage
AC input, to a 12VDC or 24VDC @ 6 amp of
continuous supply current output.
Features/Specifications
12VDC or 24VDC selectable output. 6 amp
continuous supply current.
Transformer Input requirements:
28VAC/175VA for both 12VDC or 24VDC
output (Altronix Model # T2428175).
Filtered and electronically regulated outputs.
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type
battery backup.Maximum charge current .7 amp.
Zero voltage drop upon transfer to battery backup.
AC input and DC output LED indicators.
AC fail supervision (form "C" contact rated @ 1
amp 28VDC). Low battery and battery
presence supervision (form "C" contact rated @ 1
amp 28VDC). Lifetime Warranty.
Board:
Dimensions (approximate):
7"L x 4.25 "W x 1.75 "H
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~2
Normal Stocking Item.
12/24 6A P.S. W/ BOX
Model SMP7PMCTX power supply/charger converts a
115VAC 50/60Hz input to a 12VDC or 24VDC output. It
provides 6 amp of continuous supply current. Model
SMP7CTX is a non-supervised version of this unit.
Features/Specifications
12VDC or 24VDC selectable output
6 amp of continuous supply current output
115VAC 50/60Hz, 1.45 amp input.
Filtered and electronically regulated outputs
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type battery backup
Maximum charge current .7 amp Zero voltage drop upon transfer
to battery backup. AC input and DC output LED indicators.
AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
Low battery supervision (form "C" contact rated @ 1 amp 28VDC).
Power supply, enclosure, cam lock, transformer and
battery leads.
Lifetime Warranty
Enclosure
Accommodates up to two (2) 12VDC/7AH batteries
Dimensions:
13.5"H x 13"W x 3.25"D
1/2" and 3/4" combination knockouts
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
POWER SUPPLY MODULE
When the job is too large for a conventional control, the NX-320 expands the options of the NetworX NX-8. This "Smart Power Supply" can provide up to 2 amps of additional 12 volt auxiliary power.
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~1
Normal Stocking Item.
TRANSFORMER FOR NX8-CF
REPLACEMENT
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
16.5 VOLT 40 VA TRANSFORMER W/
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~22
Normal Stocking Item.
Page 2 --- Showing records 51 - 74 (out of 74)
| Item # |
Description |
Price |
Cart |
24VAC 40VA XFMR W/AUTO RES
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~25
Normal Stocking Item.
6,12,24V PWR SUPPLY
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~10
Normal Stocking Item.
CELL PACK
You must be logged in to request more information about products.
Login or Call
for Pricing.
Clearance Item
(call to verify pricing
and availability)
CANNED POWER SUPPLY
12VDC MULTI-PURPOSE POWER SUPPLY W/ METAL CAN. AUTO RESETTING. AC & DC SURGE SUPPRESSION. 7.5" W X 12.5" H X 3.75" D. 5 AMP BATTERY
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
ESD-SPS202LC16
Manufacturer: n/a
16CH 20A 12/24VDC PWR SPLYCHGR
SPS-202LC16 = SPS-20EL with 2 PDM-8C-150-185 with 16 1.5A PTC Circuit Breaker Outputs - These output are Class II power limited
SPS-20 Features:
The SPS-20 has two 12vdc at 10A (8 Amp Rating) Outputs that can be connected in Parallel or Series to provide 12vdc, 24vdc, or 12vdc & 24vdc.
Outputs 1 and 2 are fully isolated, Independent Power Supplies.
Efficient Off-Line Switching Power Supply
Self Contained, No External Transformer required
120/240VAC Operation
Extraordinary Brown Out Capability
Precise Battery Regulation for Lead Acid Battery(s)
LED's Indicate AC and DC Outputs 1 & 2
Relay Contacts Indicates AC Power Status
Battery Online, No Drop or Switch Over with AC Power Fail
Auto Resetting circuit breaker for Battery(s) Over Current Protection with Reverse battery protection
Electronic Power Limited and Short Circuit Protection on each output
Each output has Thermal shut down with auto restart
Quality Manufactured in the USA
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~1
Special Order Item.
ESD-SPS20ELD16
Manufacturer: n/a
16CH 20A 12VDC CCTV POWER SUPP
14" x 14" x 4.75" Enclosure
12/24VDC
Power supply/charger
Contains: (2) PDM-8-100-200 with (16) 2A 3AGC fused outputs
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
12VDC 1A FUSE TXFMR
12VDC 1 amp plug in transient protected transformer. Auto resetting poly fuses.
Grounded, LED power indicator
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~12
Normal Stocking Item.
24VDC 1A FUSE TXFMR
24VDC 1 amp plug in transient protected transformer. Auto resetting poly fuses.
Grounded, LED power indicator
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~18
Normal Stocking Item.
POWER SUPPLY FOR KALATEL DVMRE
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
24VDC 5 AMP BATTERY 4" H X 3.
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
POWER SUPPLY 24VDC 4AMP
Recommended where an interface with a fire alarm system or battery backup is needed. The BPS linear power supply delivers more current than PSPs, and all BPS models are UL Class 2 listed, allowing for wire runs without the use of conduit from power supply to door.
Specification Sheet: MAG-BPS-24-4.pdf
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
24VDC PWR SUPPLY MONITOR
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
POWER SUPPLY/18 VOLT
You must be logged in to request more information about products.
Login or Call
for Pricing.
Clearance Item
(call to verify pricing
and availability)
POWER SUPPLY 12VDC 1 AMP
POWER SUPPLY 12VDC 1 AMP
Keywords:
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~1
Special Order Item.
SEC-ST1212RO5A
Manufacturer: n/a
12 VDC 500 MA REGULATED TRANS.
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
SEC-STUV12S.0Q
Manufacturer: n/a
POWER SUPPLY THIN DC12V 2 AMP
POWER SUPPLY
•Sideways plug for ease of use on power strips.
•Universal 100-240VAC input.
•Regulated 12VDC output.
•6-Foot cord 2.1mm plug (positive center).
•Low power consumption
You must be logged in to request more information about products.
Login or Call
for Pricing.
Special Order Item.
2 AMP POWER SUPPLY BOARD
SAME AS STE-LFB-50 EXCEPT BOARD ONLY. NO ENCLOSURE.
FOR CELLULAR BACK-UP POWER.
You must be logged in to request more information about products.
Login or Call
for Pricing.
Normal Stocking Item.
CELLULAR POWER SUPPLY & CAN
2 AMP. METAL ENCLOSURE WITH ANTENNA HOLE IN TOP TO FIT NEW DIGITAL UPLINK UNITS. INCLUDES CHARGING CIRCUIT FOR STAND-BY BATTERY.
You must be logged in to request more information about products.
Login or Call
for Pricing.
Clearance Item
(call to verify pricing
and availability)
TR-12500MA
Manufacturer: n/a
12V DC TRANSFORMER-SELECTABLE
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~3
Normal Stocking Item.
DC 12V 300MA (CENTER POS)
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~5
Normal Stocking Item.
DC 12V 500MA REGULATD
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~9
Normal Stocking Item.
DC 12V 1000MA/REGLTD
The RTD12/10RT is a Class II U.L. 12VDC Regulated 1000mA Power
Supply with Red LED indicator for power supervision, and built in cable
strain relief. Its construction is a bright decorator white colored plastic.
It comes with a mounting tab and mounting screw. Its compact design,
as well as its decorator color, makes it perfectly suitable for office or
residential decors.
Specification Sheet: TR-DC121000R.pdf
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~7
Normal Stocking Item.
DC 24V 500MA/CTR POS
The RTD24/5RT is a Class II U.L. 24VDC Regulated 500mA Power
Supply with Red LED indicator for power supervision, and built in cable
strain relief. Its construction is a bright decorator white colored plastic.
It comes with a mounting tab and mounting screw. Its compact design,
as well as its decorator color, makes it perfectly suitable for office or
residential decors.
Specification Sheet: TR-DC240500.pdf
You must be logged in to request more information about products.
Login or Call
for Pricing.
Qty: ~7
Normal Stocking Item.
POWER SUPPLY FOR GS-2000
This unit is the universal power
supply for use as a replacement
for any of the ChromStar series
of Winegard Pre-amplifier. This unit
has a 110 VAC input and outputs 18 VAC.
You must be logged in to request more information about products.
Login or Call
for Pricing.
Normal Stocking Item.